BUSS FRS-R-70
MFG #FRS-R-70
UPC #05171250840
SKU #23991
Product description
BUSS FRS-R-70 70AMP 600VAC/300VDC CLASS RK5 TIME-DELAY CURRENT LIMITING FUSE REJECTION TYPE
Bussmann Fusetronâ„¢ Time Delay Fuse, Advanced Protection Current Limiting Energy Efficient Low Voltage, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 70 A, 600 VAC/300 VDC, 200 kA Interrupt, Class: RK5, 10 s at 500% Response, Blade Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 1.11 in Dia x 7.88 in L Body Size
Bussmann Fusetronâ„¢ Time Delay Fuse, Advanced Protection Current Limiting Energy Efficient Low Voltage, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 70 A, 600 VAC/300 VDC, 200 kA Interrupt, Class: RK5, 10 s at 500% Response, Blade Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 1.11 in Dia x 7.88 in L Body Size
- Branch Circuit, Power Panelboard, Motor Control Centers, Combination Starter and Machinery Disconnects, Safety and Security Systems
- Bussmann Fusetron Time Delay Fuse, Current Limiting Renewable, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 70 A, 600 VAC/300 VDC, 200 kA Interrupt, Class: RK5, 10 s at 500% Response, Blade Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 1.11 in Dia x 7.88 in L Body Size
- When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full-load amps to give maximum overcurrent protection
The time delay feature makes it possible to use fuse amperage ratings which are much smaller than those of non-time delay fuses
Considerable cost saving occurs by permitting the use of smaller size switches, panels and fuses themselves
Provides a good deg of short circuit protection (greater current limitation) to help protect downstream components from high fault currents
Gives motor running back up protection to motors without extra costs
Helps protect motors against burnout from overloads and single phasing when sized properly
Simplifies and improves blackout prevention (selective coordination ratios)
Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
- FUSE DLY TIME 70A 600 VAC/300 VDC 200KA
- Product Catalog Page(s)
Specification Sheet
- CE Certified|CSA File No. 53787 C22.2/248.12 1422-02|UL 248-12/File No. E4273|UL Guide JDDZ
- Brand:Â BUSSMANNAmperage Rating:Â 70 AApplication:Â Ind Facilities & Factories - Facility: Safety and Security SystemsClass:Â Class RK5Connection:Â Blade end x blade endCountry of Origin:Â MXElement:Â DualInterrupt Rating:Â 20 kAIC at 300 Vdc200 kAIC at 600 VacResponse Time:Â 10 S at 500%Size:Â 1.11 In Diameter X 7.88 In LengthSpecial Features:Â RenewableStandard:Â CE MarkedSub Brand:Â Bussmann SeriesType:Â FuseType Of Indicators:Â Non-IndicatingVoltage Rating:Â 600 Vac, 300 Vdc