Filter
3143 items
content loaded
Part #MERSEN MPDBC6263 SAFETY COVER FOR MINI MPDB FOR USE W/MPDB62 -MPDB63 SERIES Mersen Safety Cover, Hinged, For Use With: MPDB Miniature Series Open Style Power Distribution Block, Specifications: 600 VAC, Snap-On Mount, Polycarbonate
MFG #MPDBC6263
391 in Stock. More available 11/12/2026
$12.63/EA
Part #MERSEN TRS30R 30AMP 600VAC/300VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TRS-R, Non-Indicating, Rejection, 30 A, 600 VAC/300 VDC, 200/20 kA Interru
MFG #TRS30R
585 in Stock. More available 11/19/2026
$60.32/EA
Part #MERSEN ATDR20 20AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting North American Time Delay, Series: ATDR, Non-Indicating, Rejection, 20 A,
MFG #ATDR20
391 in Stock. More available 11/26/2026
$74.88/EA
Part #MERSEN TR30R 30AMP 250VAC/160VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TR-R, Non-Indicating, Rejection, 30 A, 250 VAC/160 VDC, 200/20 kA Interrupt
MFG #TR30R
525 in Stock. More available 11/15/2026
$28.11/EA
Part #MERSEN TRS20R 20AMP 600VAC/300VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TRS-R, Non-Indicating, Rejection, 20 A, 600 VAC/300 VDC, 200/20 kA Interru
MFG #TRS20R
591 in Stock. More available 11/26/2026
$60.32/EA
Part #MERSEN ATDR30 30AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting North American Time Delay, Series: ATDR, Non-Indicating, Rejection, 30 A,
MFG #ATDR30
197 available today. Please contact inside sales for delivery information.
$74.73/EA
Part #MERSEN ATDR15 15AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting North American Time Delay, Series: ATDR, Non-Indicating, Rejection, 15 A,
MFG #ATDR15
440 in Stock. More available 11/30/2026
$74.73/EA
Part #MERSEN ATDR10 10AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting North American Time Delay, Series: ATDR, Non-Indicating, Rejection, 10 A,
MFG #ATDR10
291 in Stock. More available 11/14/2026
$74.73/EA
Part #MERSEN TR15R 15AMP 250VAC/160VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECIION TYPE Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TR-R, Non-Indicating, Rejection, 15 A, 250 VAC/160 VDC, 200/20 kA Interrupt
MFG #TR15R
319 in Stock. More available 10/28/2026 and 12/05/2026
$28.08/EA
Part #MERSEN GDG1/2 1/2AMP 250VAC GLASS FUSE TIME- DELAY 5MM X 20MM Mersen Miniature Fuse, Time Delay, Series: GDG, Non-Rejection, 0.5 A, 250 VAC, 0.035 kA Interrupt, Ferrule Terminal, Clip Mounting, Cylindrical Body, Glass, Clear, 5 mm Dia x 20 mm L Body
MFG #GDG1/2
45 in Stock. More available 11/12/2026
$6.58/EA
Part #MERSEN ATQR15 15AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECITON TYPE Mersen Amp-Trap® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series: ATQR, Non-Indicating, Rejec
MFG #ATQR15
283 in Stock. More available 11/14/2026
$72.74/EA
Part #MERSEN TR20R 20AMP 250VAC/160VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TR-R, Non-Indicating, Rejection, 20 A, 250 VAC/160 VDC, 200/20 kA Interrupt
MFG #TR20R
437 in Stock. More available 11/27/2026
$28.11/EA
Part #MERSEN TRS15R 15AMP 600VAC/300VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Littelfuse® Time Delay Fuse, Series: FLSR, 15 A, 600 VAC, 300/20 kA Interrupt, Class: RK5, Dual Element, 13/16 in Dia x 5 in L Body Size
MFG #TRS15R
320 in Stock. More available 10/24/2026 and 11/20/2026
$60.32/EA
Part #MERSEN ATM10 10AMP 600VAC/VDC MIDGET CLASS FAST ACTING FUSE 1-1/2" X 13/32" Mersen Amp-Trap® Fast Acting Fuse, Low Voltage, Series: ATM, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Non-Rejection, 10 A, 600 VAC/VDC,
MFG #ATM10
94 in Stock. More available 11/12/2026
$57.12/EA
Part #MERSEN ATQR10 10AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Amp-Trap® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series: ATQR, Non-Indicating, Rejec
MFG #ATQR10
202 in Stock. More available 11/12/2026
$77.19/EA
Part #MERSEN TR60R 60AMP 250VAC/VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TR-R, Non-Indicating, Rejection, 60 A, 250 VAC/VDC, 200/20 kA Interrupt, Class
MFG #TR60R
246 in Stock. More available 11/12/2026
$51.52/EA
Part #MERSEN ATQR1/2 1/2AMP 600VAC/300VDC CLASS CC TIME-DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Amp-Trap® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series: ATQR, Non-Indicating, Reje
MFG #ATQR1/2
81 available today. Please contact inside sales for delivery information.
$73.21/EA
Part #MERSEN AJT30 30AMP 600VAC/500VDC CLASS J TIME- DELAY CURRENT LIMITING FUSE W/BLOWN FUSE INDICATOR IEC TYPE 2 PROTECTION Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series:
MFG #AJT30
134 in Stock. More available 11/15/2026
$91.98/EA
Part #MERSEN ATDR3 3AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series: ATDR, Non-Indicating, Rejecti
MFG #ATDR3
178 in Stock. More available 12/05/2026
$74.73/EA
Part #MERSEN TRS60R 60AMP 600VAC/300VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TY 84603 Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TRS-R, Non-Indicating, Rejection, 60 A, 600 VAC/300 VDC, 200/20 kA Int
MFG #TRS60R
270 in Stock. More available 11/20/2026
$103.44/EA
Part #MERSEN ATQR2 2AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Amp-Trap® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series: ATQR, Non-Indicating, Rejecti
MFG #ATQR2
234 in Stock. More available 11/14/2026
$73.34/EA
Part #MERSEN AJT15 15AMP 600VAC/500VDC CLASS J TIME- DELAY CURRENT LIMITING FUSE W/BLOWN FUSE INDICATOR IEC TYPE 2 PROTECTION Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series:
MFG #AJT15
71 in Stock. More available 11/15/2026
$91.98/EA
Part #MERSEN GGC2 2AMP 250VAC GLASS FUSE FAST ACTING 1/4" X 1-1/4" Mersen Miniature Fuse, Fast Acting, Series: GGC, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Non-Rejection, 2 A, 250 VAC, 0.2 kA Interrupt, Ferrule Terminal, Clip Mo
MFG #GGC2
216 in Stock. More available 11/12/2026
$2.10/EA
Part #MERSEN TR50R 50AMP 250VAC/VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TR-R, Non-Indicating, Rejection, 50 A, 250 VAC/VDC, 200/20 kA Interrupt, Class
MFG #TR50R
221 in Stock. More available 11/14/2026
$51.52/EA
Part #MERSEN MPDBC6263 SAFETY COVER FOR MINI MPDB FOR USE W/MPDB62 -MPDB63 SERIES Mersen Safety Cover, Hinged, For Use With: MPDB Miniature Series Open Style Power Distribution Block, Specifications: 600 VAC, Snap-On Mount, Polycarbonate
MFG #MPDBC6263
391 in Stock. More available 11/12/2026
$12.63/EA
Part #MERSEN TRS30R 30AMP 600VAC/300VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TRS-R, Non-Indicating, Rejection, 30 A, 600 VAC/300 VDC, 200/20 kA Interru
MFG #TRS30R
585 in Stock. More available 11/19/2026
$60.32/EA
Part #MERSEN ATDR20 20AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting North American Time Delay, Series: ATDR, Non-Indicating, Rejection, 20 A,
MFG #ATDR20
391 in Stock. More available 11/26/2026
$74.88/EA
Part #MERSEN TR30R 30AMP 250VAC/160VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TR-R, Non-Indicating, Rejection, 30 A, 250 VAC/160 VDC, 200/20 kA Interrupt
MFG #TR30R
525 in Stock. More available 11/15/2026
$28.11/EA
Part #MERSEN TRS20R 20AMP 600VAC/300VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TRS-R, Non-Indicating, Rejection, 20 A, 600 VAC/300 VDC, 200/20 kA Interru
MFG #TRS20R
591 in Stock. More available 11/26/2026
$60.32/EA
Part #MERSEN ATDR30 30AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting North American Time Delay, Series: ATDR, Non-Indicating, Rejection, 30 A,
MFG #ATDR30
197 available today. Please contact inside sales for delivery information.
$74.73/EA
Part #MERSEN ATDR15 15AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting North American Time Delay, Series: ATDR, Non-Indicating, Rejection, 15 A,
MFG #ATDR15
440 in Stock. More available 11/30/2026
$74.73/EA
Part #MERSEN ATDR10 10AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting North American Time Delay, Series: ATDR, Non-Indicating, Rejection, 10 A,
MFG #ATDR10
291 in Stock. More available 11/14/2026
$74.73/EA
Part #MERSEN TR15R 15AMP 250VAC/160VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECIION TYPE Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TR-R, Non-Indicating, Rejection, 15 A, 250 VAC/160 VDC, 200/20 kA Interrupt
MFG #TR15R
319 in Stock. More available 10/28/2026 and 12/05/2026
$28.08/EA
Part #MERSEN GDG1/2 1/2AMP 250VAC GLASS FUSE TIME- DELAY 5MM X 20MM Mersen Miniature Fuse, Time Delay, Series: GDG, Non-Rejection, 0.5 A, 250 VAC, 0.035 kA Interrupt, Ferrule Terminal, Clip Mounting, Cylindrical Body, Glass, Clear, 5 mm Dia x 20 mm L Body
MFG #GDG1/2
45 in Stock. More available 11/12/2026
$6.58/EA
Part #MERSEN ATQR15 15AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECITON TYPE Mersen Amp-Trap® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series: ATQR, Non-Indicating, Rejec
MFG #ATQR15
283 in Stock. More available 11/14/2026
$72.74/EA
Part #MERSEN TR20R 20AMP 250VAC/160VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TR-R, Non-Indicating, Rejection, 20 A, 250 VAC/160 VDC, 200/20 kA Interrupt
MFG #TR20R
437 in Stock. More available 11/27/2026
$28.11/EA
Part #MERSEN TRS15R 15AMP 600VAC/300VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Littelfuse® Time Delay Fuse, Series: FLSR, 15 A, 600 VAC, 300/20 kA Interrupt, Class: RK5, Dual Element, 13/16 in Dia x 5 in L Body Size
MFG #TRS15R
320 in Stock. More available 10/24/2026 and 11/20/2026
$60.32/EA
Part #MERSEN ATM10 10AMP 600VAC/VDC MIDGET CLASS FAST ACTING FUSE 1-1/2" X 13/32" Mersen Amp-Trap® Fast Acting Fuse, Low Voltage, Series: ATM, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Non-Rejection, 10 A, 600 VAC/VDC,
MFG #ATM10
94 in Stock. More available 11/12/2026
$57.12/EA
Part #MERSEN ATQR10 10AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Amp-Trap® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series: ATQR, Non-Indicating, Rejec
MFG #ATQR10
202 in Stock. More available 11/12/2026
$77.19/EA
Part #MERSEN TR60R 60AMP 250VAC/VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TR-R, Non-Indicating, Rejection, 60 A, 250 VAC/VDC, 200/20 kA Interrupt, Class
MFG #TR60R
246 in Stock. More available 11/12/2026
$51.52/EA
Part #MERSEN ATQR1/2 1/2AMP 600VAC/300VDC CLASS CC TIME-DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Amp-Trap® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series: ATQR, Non-Indicating, Reje
MFG #ATQR1/2
81 available today. Please contact inside sales for delivery information.
$73.21/EA
Part #MERSEN AJT30 30AMP 600VAC/500VDC CLASS J TIME- DELAY CURRENT LIMITING FUSE W/BLOWN FUSE INDICATOR IEC TYPE 2 PROTECTION Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series:
MFG #AJT30
134 in Stock. More available 11/15/2026
$91.98/EA
Part #MERSEN ATDR3 3AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series: ATDR, Non-Indicating, Rejecti
MFG #ATDR3
178 in Stock. More available 12/05/2026
$74.73/EA
Part #MERSEN TRS60R 60AMP 600VAC/300VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TY 84603 Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TRS-R, Non-Indicating, Rejection, 60 A, 600 VAC/300 VDC, 200/20 kA Int
MFG #TRS60R
270 in Stock. More available 11/20/2026
$103.44/EA
Part #MERSEN ATQR2 2AMP 600VAC/300VDC CLASS CC TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Amp-Trap® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series: ATQR, Non-Indicating, Rejecti
MFG #ATQR2
234 in Stock. More available 11/14/2026
$73.34/EA
Part #MERSEN AJT15 15AMP 600VAC/500VDC CLASS J TIME- DELAY CURRENT LIMITING FUSE W/BLOWN FUSE INDICATOR IEC TYPE 2 PROTECTION Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series:
MFG #AJT15
71 in Stock. More available 11/15/2026
$91.98/EA
Part #MERSEN GGC2 2AMP 250VAC GLASS FUSE FAST ACTING 1/4" X 1-1/4" Mersen Miniature Fuse, Fast Acting, Series: GGC, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Non-Rejection, 2 A, 250 VAC, 0.2 kA Interrupt, Ferrule Terminal, Clip Mo
MFG #GGC2
216 in Stock. More available 11/12/2026
$2.10/EA
Part #MERSEN TR50R 50AMP 250VAC/VDC CLASS RK5 TIME- DELAY CURRENT LIMITING FUSE REJECTION TYPE Mersen Tri-Onic® Time Delay Fuse, Current Limiting Low Voltage, Series: TR-R, Non-Indicating, Rejection, 50 A, 250 VAC/VDC, 200/20 kA Interrupt, Class
MFG #TR50R
221 in Stock. More available 11/14/2026
$51.52/EA





























