MFG #CH2L125SP
UPC #78211419047
SKU #3805811
Product description
CH CH2L125SP 125AMP MAIN LUG (2)1POLE SPACE (4) CIRCUIT 120/240VAC 1PHASE 3WIRE COPPER BUS TYPE CH LOADCENTER NEMA1 SURFACE TRIM NO DOOR
EATON Main Lug Load Center, 1-Phase Standard, 120/240 VAC, 125 A, 4 Pole, 25 kA Interrupt, 2 Circuits, CH Breaker, 3-Wire Wiring Configuration, 125 A Bus, 2 Spaces, 4/0 to 1 AWG Wire, Surface/Plug-On Mounting, NEMA 1 Enclosure, NEMA 6 Enclosure Box, Metal Housing Material, 9.5 in L x 4.5 in W x 3.13 in H Dimensions
EATON Main Lug Load Center, 1-Phase Standard, 120/240 VAC, 125 A, 4 Pole, 25 kA Interrupt, 2 Circuits, CH Breaker, 3-Wire Wiring Configuration, 125 A Bus, 2 Spaces, 4/0 to 1 AWG Wire, Surface/Plug-On Mounting, NEMA 1 Enclosure, NEMA 6 Enclosure Box, Metal Housing Material, 9.5 in L x 4.5 in W x 3.13 in H Dimensions
- Industrial Facilities, Factories - Power Distribution, Control, Commercial and Residential Applications
- EATON Main Lug Load Center, 1-Phase Standard, 120/240 VAC, 125 A, 4 Pole, 25 kA Interrupt, 2 Circuits, CH Breaker, 3-Wire Wiring Configuration, 125 A Bus, 2 Spaces, 4/0 to 1 AWG Wire, Surface/Plug-On Mounting, NEMA 1 Enclosure, NEMA 6 Enclosure Box, Metal Housing Material, 9.5 in L x 4.5 in W x 3.13 in H Dimensions
- Steel backpan provides positive, reliable mounting
Unique sandalwood finish provides an esthetically appealing, scratch resistant powder coating
Type CH breakers include an industry exclusive "trip to Off" feature that allows a homeowner to easily identify a tripped circuit breaker
Mechanical flag feature on CH breakers for easy trip indication
Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard
Overhead/underground feed applications
Insulated/bondable single neutral
Copper bus
- CENTER LOAD LUG MAIN 120/240VAC 125A 4
- Product Catalog Page(s)
Specification Sheet
- UL 50|UL 67
- Brand: Eaton Cutler Hammer DistributionAmperage Rating: 125 AApplication: Ind Facilities & Factories - Facility: Power Distribution and ControlCommercial / Institutional Buildings / Structures - Power Distribution and ControlsCable Size: #1-4/0 AWGCircuit Breaker Type: CHCountry of Origin: USEnclosure: NEMA 1Interrupt Rating: 25 kAICMounting: SURFACENumber Of Feeders: Overhead or undergroundNumber Of Spaces: 2Phase: Single-phaseSize: 6Special Features: StandardStandard: UL 50|UL 67Type: Main lug loadcenterVoltage Rating: 120/240 VWattage: Four-poleWiring Configuration: Three-wire