CH BR255 BR Circuit Breaker
EATON Thermal Magnetic Circuit Breaker, Type BR, 120/240 VAC, 55 A, 60 Hz, 10 kAIC Interrupt, Common Trip, 2 Pole, Toggle Handle Actuator, Box Lug/Clamp, 14 to 3 AWG Copper/Aluminum Wire, Plug-On Mount, 40 deg C, 3 in L x 2 in W x 3 in H, Thermoset
EATON Thermal Magnetic Circuit Breaker, Type BR, 120/240 VAC, 55 A, 60 Hz, 10 kAIC Interrupt, Common Trip, 2 Pole, Toggle Handle Actuator, Box Lug/Clamp, 14 to 3 AWG Copper/Aluminum Wire, Plug-On Mount, 40 deg C, 3 in L x 2 in W x 3 in H, Thermoset
- Generation, Renewable Energy, Alternative Energy, Conventional Energy, Conventional Energy, Datacenters, CI and Hyper Converged IT Space, Marine Vessels and Equipment
- EATON Thermal Magnetic Circuit Breaker, Type BR, 120/240 VAC, 55 A, 60 Hz, 10 kAIC Interrupt, Common Trip, 2 Pole, Toggle Handle Actuator, Box Lug/Clamp, 14 to 3 AWG Copper/Aluminum Wire, Plug-On Mount, 40 deg C, 3 in L x 2 in W x 3 in H, Thermoset
- Each pole of the circuit breaker will provide inverse time delay overload and instantaneous short circuit protection by means of both thermal and magnetic sensors
The circuit breaker calibration shall not be affected by environmental changes in relative humidity
All circuit breakers shall be operated by a toggle type handle and multipole circuit breakers shall have an internal common trip mechanism
Contacts shall be of non-welding silver alloy
All circuit breakers shall have the trip rating inscribed on the handle on each circuit breaker pole
Circuit breakers shall be completely enclosed in a molded case of thermoset material
All terminals shall be listed for use with copper or aluminum conductors
Terminals shall be of the box lug or clamp-type design
The terminals shall meet UL 486B requirements and shall be suitable for use with either 60 or 75 deg C wire
1 in per pole
- BREAKER CKT MAG THRM 120/240VAC 55A 2
- Product Catalog Page(s)
Specification Sheet
- UL 489|Federal Specification W-C375
- Brand: Eaton Cutler Hammer DistributionAmperage Rating: 55 AApplication: Datacenters - IT Space: CI and Hyper ConvergedGeneration - Renewable Energy - Alternative EnergyGeneration - Conventional Energy - Conventional EnergyMarine Vessels and Equipment - Marine Vessels and Equipment - OtherOtherCountry of Origin: DOHeight: 3 inInterrupt Rating: 10 kAICLength: 3Number of Poles: Two-poleStandard: UL 489,Federal Specifications Classification W-C375Sub Brand: NoneTrip Type: Common breaker tripType: Thermal magnetic circuit breakersVoltage Rating: 120/240 VWidth: 2