MFG #FRS-R-50
UPC #05171250838
SKU #23982
Product description
BUSS FRS-R-50 600VAC/300VDC 50AMP CLASS RK5 TIME-DELAY CURRENT LIMITING FUSE REJECTION TYPE
Bussmann Fusetronâ„¢ Time Delay Fuse, Advanced Protection Current Limiting Energy Efficient Low Voltage, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 50 A, 600 VAC/250 VDC, 20/200 kA Interrupt, Class: RK5, 10 s at 500% Response, Ferrule Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 1.06 in Dia x 5.5 in L Body Size
Bussmann Fusetronâ„¢ Time Delay Fuse, Advanced Protection Current Limiting Energy Efficient Low Voltage, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 50 A, 600 VAC/250 VDC, 20/200 kA Interrupt, Class: RK5, 10 s at 500% Response, Ferrule Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 1.06 in Dia x 5.5 in L Body Size
- Branch Circuit, Power Panelboard, Motor Control Centers, Combination Starter and Machinery Disconnects, Safety and Security Systems
- Bussmann Fusetronâ„¢ Time Delay Fuse, Advanced Protection Current Limiting Energy Efficient Low Voltage, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 50 A, 600 VAC/250 VDC, 20/200 kA Interrupt, Class: RK5, 10 s at 500% Response, Ferrule Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 1.06 in Dia x 5.5 in L Body Size
- Closer sizing allows for smaller fuses and less costly switches
Class RK5 fuses with a 200 kA interrupt rating for use in a broad range of applications
Provides motor overload, ground fault and short circuit protection
Helps protect motors against burnout from overloads and single phasing when sized properly
Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
Offers a 10 sec time delay at 5 times the rated current
The time delay feature makes it possible to use fuse amperage ratings which are much smaller than those of non-time delay fuses
Considerable cost saving occurs by permitting the use of smaller size switches, panels and fuses themselves
Provides current limitation to help protect downstream components from high fault currents
Gives motor running back up protection to motors without extra costs
- FUSE DLY TIME 50A 600 VAC/250 VDC RK5
- Product Catalog Page(s)
Specification Sheet
- CE Certified|CSA C22.2 No. 248.12/1422-02/File No. 53787|UL 248-12/File No. E4273|UL Guide JDDZ
- Brand: BUSSMANNAmperage Rating: 50 AApplication: Ind Facilities & Factories - Facility: Safety and Security SystemsClass: Class RK5Connection: Ferrule end x ferrule endCountry of Origin: MXElement: DualInterrupt Rating: 20 kAIC at 250 Vdc200 kAIC at 600 VacResponse Time: 10 S at 500%Size: 1.06 In Diameter X 5.50 In LengthSpecial Features: RenewableStandard: CE MarkedSub Brand: Bussmann SeriesType: FuseType Of Indicators: Non-IndicatingVoltage Rating: 600 Vac, 250 Vdc