MFG #LP-CC-25
UPC #05171218028
SKU #24742
Product description
BUSS LP-CC-25 600VAC/300VDC 30AMP CLASS CC LOW-PEAK TIME-DELAY CURRENT LIMITING FUSE 13/32" X 1-1/2" REJECTION TYPE
Bussmann Low-Peakâ„¢ Time Delay Fuse, Current Limiting, Series: LP-CC, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 25 A, 600 VAC/300 VDC, 20/200 kA Interrupt, Class: CC, 12 s at 200% Response, Ferrule Terminal, Holder Mount, Cylindrical Body Type, Dual Element, Melamine, Yellow, 13/32 in Dia x 1-1/2 in L Body Size
Bussmann Low-Peakâ„¢ Time Delay Fuse, Current Limiting, Series: LP-CC, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 25 A, 600 VAC/300 VDC, 20/200 kA Interrupt, Class: CC, 12 s at 200% Response, Ferrule Terminal, Holder Mount, Cylindrical Body Type, Dual Element, Melamine, Yellow, 13/32 in Dia x 1-1/2 in L Body Size
- Branch Circuits, Specialized Circuits, Industrial Control and Street Lighting Applications, Safety and Security Systems
- Bussmann Low-Peakâ„¢ Time Delay Fuse, Current Limiting, Series: LP-CC, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 25 A, 600 VAC/300 VDC, 20/200 kA Interrupt, Class: CC, 12 s at 200% Response, Ferrule Terminal, Holder Mount, Cylindrical Body Type, Dual Element, Melamine, Yellow, 13/32 in Dia x 1-1/2 in L Body Size
- Fast short circuit protection and dual element, time delay performance provide ultimate protection
Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak™ fuses
Consistent 2:1 ampacity ratios for all Low-Peak™ fuses make selective coordination easy
Time delay characteristic avoids unwanted fuse openings from surge currents while fast response speed under short circuit conditions provides a high degree of current limitation
Current limitation protects downstream components against damaging thermal and magnetic effects of short circuit currents
A superior, all purpose, space saving branch circuit fuse that meets most protection requirements up to 30 A
Very compact, with a physical size only 13/32 x 1-1/2 in with rejection tip
Proper sizing can provide "no damage" type 2 coordinated protection for NEMA and IEC motor controllers
Can be used where either a time delay or a fast acting fuse is needed, making selection easier and reducing spare fuse inventories for substantial cost reduction
Superior protection for small horsepower motor circuit
12 s (minimum) at 200% of rated current response time
200 kA at 600 VAC RMS symmetrical, 20 kA at 300 VDC (UL 198L) interrupt rating
- FUSE DLY TIME 25A 600 VAC/300 VDC CC CYL
- Product Catalog Page(s)
Specification Sheet
- CE Certified|CSA C22.2/1422-02|CSA File No. 53787|RoHS Compliant|UL 248-4|UL File No. E4273|UL Guide JDDZ
- Brand: BUSSMANNAmperage Rating: 25 AApplication: Ind Facilities & Factories - Facility: Safety and Security SystemsClass: Class CCConnection: Ferrule end x ferrule endCountry of Origin: MULElement: DualInterrupt Rating: 200 kAIC at 600 Vac20 kAIC at 300 VdcMaterial: Melamine TubeResponse Time: 12 S at 200%Size: 13/32 In Diameter X 1-1/2 In LengthSpecial Features: Rejection StyleStandard: CSA Certified ,UL Listed,RoHS Compliant,CE MarkedSub Brand: Bussmann SeriesType: FuseType Of Indicators: Non-IndicatingVoltage Rating: 600 Vac, 300 Vdc