BUSS LPJ-30SP 600VAC/300VDC 30AMP CLASS J LOW-PEAK TIME-DELAY CURRENT LIMITING FUSE
Bussmann Low-Peak® Time Delay Fuse, Current Limiting, Series: LPJ-SP, Non-Indicating, Non-Rejection, 30 A, 600 VAC/300 VDC, 100/300 kA Interrupt, Class: J, 10 s Response, Ferrule Terminal, Holder Mount, Cartridge Body Type, Dual Element, Melamine, 0.81 in Dia x 2.25 in L Body Size
Bussmann Low-Peak® Time Delay Fuse, Current Limiting, Series: LPJ-SP, Non-Indicating, Non-Rejection, 30 A, 600 VAC/300 VDC, 100/300 kA Interrupt, Class: J, 10 s Response, Ferrule Terminal, Holder Mount, Cartridge Body Type, Dual Element, Melamine, 0.81 in Dia x 2.25 in L Body Size
- Power Panelboard, Branch Circuit Breaker Panelboard Mains, Machinery Disconnects and Industrial Control
- Bussmann Low-Peak® Time Delay Fuse, Current Limiting, Series: LPJ-SP, Non-Indicating, Non-Rejection, 30 A, 600 VAC/300 VDC, 100/300 kA Interrupt, Class: J, 10 s Response, Ferrule Terminal, Holder Mount, Cartridge Body Type, Dual Element, Melamine, 0.81 in Dia x 2.25 in L Body Size
- Selective coordination ratio of 2:1 (within Low-Peak® fuse family) prevents electrical shutdowns from extending beyond the failed circuit
Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer
Proper sizing can provide "No Damage" type 2 coordinated protection for NEMA® and IEC® motor controllers
Space saving package for equipment down sizing
Industry's only UL listed and CSA Certified fuse with a 300 kA interrupt rating that allows for simple, worry free installation in virtually any application
Fast short circuit protection and dual element, time delay performance provide ultimate protection
Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak® fuses
Consistent 2:1 ampacity ratios for all Low-Peak® fuses make selective coordination easy
Long time delay minimizes needless fuse openings due to temporary overloads and transient surges
Current limitation protects downstream components against damaging thermal and magnetic effects of short circuit currents
Dual element fuses have lower resistance than ordinary fuses, hence they run cooler
They can often be sized for back up protection against motor burnout from overload or single phasing if other overload protective devices fail
- FUSE DLY TIME 30A 600VAC 300VDC J 10S
- Product Catalog Page(s)
Specification Sheet
- UL Listed|Guide JDDZ, File No. E4273|CSA Class 1422-02, File No. 53787, Class J per CSA C22.2 No. 248.8|CE Certified
- Brand:Â BUSSMANNAmperage Rating:Â 30 AmpApplication:Â Ind Facilities & Factories - Facility: Safety and Security SystemsClass:Â JConnection:Â Ferrule end x ferrule endCountry of Origin:Â MXElement:Â DualInterrupt Rating:Â 300000 Amp (RMS Symmetrical UL), 100000 Amp (DC)Response Time:Â 10 S at 500%Size:Â 0.81 In Diameter X 2.25 In LengthStandard:Â UL Listed ,CSA Certified,RoHS CompliantSub Brand:Â Bussmann SeriesType:Â FuseType Of Indicators:Â Non-IndicatingVoltage Rating:Â 600 Vac, 300 Vdc